On Sat, Jan 12, 2002 at 09:57:40AM -0500, anthracite blond wrote:
> On Fri, 11 Jan 2002, Matt Mayes wrote:
> > I have lab environment with several cisco and juniper boxes. Does anyone
> > know if there exists a juniper equivalent of cdp? If so, can you point me
> > to some documentation.
> >
>
> If you're using Sonet links, both Cisco and Juniper devices will transmit
> basic device information (hostname, port name and IP address (Cisco only))
> using the path trace field.
>
> Use "show controller" or "show interfaces extensive."
That is ok - but in my experience CDP is mostly usefull when connecting
to a L2 device, as you cannot rely on L3 addresses to do the mapping of
connected interfaces.
/Jesper
-- Jesper Skriver, jesper(at)skriver(dot)dk - CCIE #5456 Work: Network manager @ AS3292 (Tele Danmark DataNetworks) Private: FreeBSD committer @ AS2109 (A much smaller network ;-)One Unix to rule them all, One Resolver to find them, One IP to bring them all and in the zone to bind them.