RE: Juniper M10 with modem management

From: Jack Maxfield (jmaxfield@juniper.net)
Date: Tue Mar 12 2002 - 09:51:33 EST


> Jack,
> According with my JTAC Engineer, console is the only port active by
> default.
>
> Is AUX active by default after 5.1 ?
>

No. The Console is the only port active by default. The Aux port
requires the configuration settings as described below. I just tested
this in JUNOS 5.2.

Jack

> German
>
> On Mon, 11 Mar 2002, Jack Maxfield wrote:
>
> > Peter,
> >
> > There are some required config settings to enable the AUX port...
> >
> > Try:
> >
> > [edit]
> > lab@routerA# set system ports auxiliary type vt100
> >
> > Regards, Jack
> >
> > > -----Original Message-----
> > > From: ProServe - Peter Batenburg [mailto:peter@proserve.nl]
> > > Sent: Monday, March 11, 2002 6:08 AM
> > > To: juniper-nsp@puck.nether.net
> > > Subject: Juniper M10 with modem management
> > >
> > >
> > > Hi,
> > >
> > > I connected a external modem to the AUX/MODEM port on our
> M10. Only
> > > problem is that the modem doesn't see an connection with the
> > > router (TR
> > > led). Are there any config options that need to be changed to
> > > make this
> > > port active? Or should it work instantly? We're running on
> > > JunOS 5.1R1.4.
> > > Thanks.
> > >
> > > Met vriendelijke groet/With kind regards,
> > >
> > > Peter Batenburg
> > >
> > > ProServe B.V.
> > >
> > >
> >
>
>



This archive was generated by hypermail 2b29 : Mon Aug 05 2002 - 10:42:40 EDT