RE: [j-nsp] ISIS adjacency problems

From: Neil Stirling (neil.stirling@nortelnetworks.com)
Date: Sun Mar 17 2002 - 18:55:44 EST


Think I know what box you're using....

Did it work without link authentication ?
Are both routers in the same level ?

Have you got a config example ?

Neil.

-----Original Message-----
From: German Martinez [mailto:gmartine@mafalda.opentransit.net]
Sent: 17 March 2002 22:56
To: HHH
Cc: juniper-nsp@puck.nether.net; juniper@groupstudy.com
Subject: Re: [j-nsp] ISIS adjacency problems

Are you using fxp0 to do any routing ?
fxp0 is a management ethernet interface and I don't think that you will be
able to establish an adjacency.

Have you tried doing the same but using other interface ?

German

On Sun, 17 Mar 2002, HHH wrote:

> Having problems with building adjacency between two test Routers. I have
authentication running between them, and I had seen authentication failure
logs, but I rechecked and retypes the hello-key's but still can't get the
adjacency to become stable. It transitions between up and down. Anyone
know what the problem could be...can u elaborate more on Designate router
mismatch..all router are running at Level 2, and I set the priority for
Router-C to 0. Any suggestions?
>
> Mar 17 13:38:50 Received L2 LAN IIH, source id Router-B on fxp0.0
> Mar 17 13:38:50 Designated router mismatch, ours Router-C, remote Router-B
> Mar 17 13:38:50 Adjacency state change, Router-B, state Up -> Down
>
> Thanks
>