Re: M20 vs. M40

From: David Mallwitz (dave@focaleng.net)
Date: Thu Jul 05 2001 - 17:35:19 EDT


I've had 2 SSB's, 1 RE, 1 hard drive and 1 internal flash fail, also had
1 corrupted flash card. All this over the past year among a deployment
of ~40 M20s. I don't consider this bad at all, since it's been pretty
easy to diagnose and we have on site spares. Keep in mind that even with
the redundant hardware the router will need to reboot, usually requiring
2-3 minutes to come back up (note to Juniper: use a journaling file
system so we can skip the fsck on unexpected reboots). I highly
recommend the M20.

Dave

On 05 Jul 2001 14:10:08 -0700, Joe McGuckin wrote:
>
> We're looking to purchase a juniper and the final question is which
> one should we get: the difference in price isn't that much and
> the M40 will save us the hassle of having to swap chassis when we start
> using up the PIC slots.
>
> The M20 does have provision for redundant SSB and Route Engines.
> Is that really necessary? Has anyone ever has an SSB or RE fail?
>
> I notice that Juniper has moved away from the LS120 floppy to flash
> cards
> for media distribution. Has anyone has problems with the LS120 drives?
>
> Comments, advice, etc are welcome!
>
> Thanks,
>
> Joe
>



This archive was generated by hypermail 2b29 : Mon Aug 05 2002 - 10:42:40 EDT