Has anyone seen the following:
dCEF stopped running and remains disabled on slot 4 and 5 of a 7507
with RSP2 and 12.0.11 IOS
eventhough the "ip route-cache distributed" command exists on
the interfaces.
On slot 0 it seems to work fine.
Do you know any workaround to enable dCEF again, without
disabling cef globaly or reloading the router?
Any known bugID for this or a similar problem?
router>sh cef linecard
CEF table version 1285259, 107741 routes
Slot CEF-ver MsgSent XdrSent Seq MaxSeq LowQ MedQ HighQ Flags
0 1285259 470221 2548790 7063 7087 0 0 0 up, sync
4 101005 1431 102797 1425 1448 0 8 0 disabled
5 0 2204 204390 783 785 0 0 0
disabled
Best Regards,
Kostas Strakadounas
FORTHnet SA