> We are trying to deploy a 7206 with a built-in FE and a channelized T3
> card. Based on TAC's response, we are running 11.1(17)CA in order to
> recognize the CT3 card. Now whenever we try to bring up the FE
> interface, it bounces up and down. TAC thought it was a bad IO
> controller, so we swapped it and the problem persists. If we run
> 11.2, the FE works fine, but the CT3 is not seen. We've also changed
> out the MII transceiver and tried different switches. Any thoughts?
I had the very same problem with the FastEthernet on a 7206 a few
months ago. I couldn't find a load that supported everything we
needed *AND* did not exhibit this problem.
But I found a workaround: turn keepalive off ("no keepalive") on the
FE interface. The problem will go away and you will not have trouble
with the FE interface.
-Phil
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:15 EDT