Re: [nsp] 7206 with CT3 and Fast Ethernet

From: Tim Flavin (tim@i1.net)
Date: Wed Feb 18 1998 - 16:24:47 EST


On Wed, 18 Feb 1998, Mark D. Nagel wrote:

> We are trying to deploy a 7206 with a built-in FE and a channelized T3
> card. Based on TAC's response, we are running 11.1(17)CA in order to
> recognize the CT3 card. Now whenever we try to bring up the FE
> interface, it bounces up and down. TAC thought it was a bad IO
> controller, so we swapped it and the problem persists. If we run
> 11.2, the FE works fine, but the CT3 is not seen. We've also changed
> out the MII transceiver and tried different switches. Any thoughts?
>

!
version 11.1
!
interface FastEthernet0/0
 ip address 209.74.155.1 255.255.255.224 secondary
 ip address 207.230.35.100 255.255.252.0
 ip ospf priority 10
 no keepalive
 media-type MII
 full-duplex
 no mop enabled
!

ROM: System Bootstrap, Version 11.1(10) [dschwart 10], RELEASE SOFTWARE
(fc1)
ROM: 7200 Software (C7200-BOOT-M), Version 11.1(13a)CA1, EARLY DEPLOYMENT
RELEASE SOFTWARE (fc1)

Works for me, hopefully for you as well, but I do not have a CT3 card in
it.

==============================================================
Tim Flavin Internet Access for St Louis & Chicago
Internet 1st, Inc Toll Free Sales & Support 800-875-3173
http://www.i1.net For more information email info@i1.net
==============================================================